Sign In | Join Free | My xxjcy.com |
|
MOQ : 100
Payment Terms : T/T
Delivery Time : 1-12 weeks
Packaging Details : Original packing
Rated measuring current IPN : 1000A
Measuring range IPM : ±2100A
Power supply voltage VC : DC±(15~24)×(1±10%)V
Current consumption IC (@±24V) : ≤±35mA+ISN
Rated measurement output ISN : 333.33mA
Turns ratio : 1:3000
Basic error δi(@IPN,TA=25℃) : ≤±0.4%
Linearity δL(@IPN,TA=25℃) : ≤±0.1%
product manual
NACL-1000B-S5/SP1 magnetic balance Hall current sensor is suitable for accurate measurement of AC, DC, and pulse current isolation. The primary side and the secondary side are completely insulated during measurement.
product advantages | Applications | Reference standard |
High precision | AC Inverter AC | GB/T 25119-2010 EN50178 EN50155 |
Good linearity | Private server motor drive | |
Low temperature drift | Battery powered | |
Broadband | Converter/Inverter | |
Quick response | UPS/SVG |
Main electrical parameters (@±IPN, TA = 25℃) | |
Rated measuring current IPN | 1000A |
Measuring range IPM | ±2100A |
Power supply voltage VC | DC±(15~24)×(1±10%)V |
Current consumption IC (@±24V) | ≤±35mA+ISN |
Rated measurement output ISN | 333.33mA |
Turns ratio | 1:3000 |
Load resistance RM |
@±15V, ±1000A: 0Ω~21Ω(70℃) 0Ω~19.5Ω(85℃) @±15V, ±1500A: 0Ω~10Ω(70℃) @±24V, ±1000A: 8.5Ω~48.5Ω(70℃) 10Ω~54Ω(85℃) @±24V, ±2100A: 10Ω~14Ω(70℃) |
Accuracy-dynamic parameters | |
Basic error δi(@IPN,TA=25℃) | ≤±0.4% |
Linearity δL(@IPN,TA=25℃) | ≤±0.1% |
Zero output current IO (@IP=0, TA = 25℃) | ≤±0.5mA |
Zero temperature drift IOT | ≤±0.8mA |
Response time TR (90% of IPN&di/dt> 50 A/µS) |
≤1µS |
General data | |
Working temperature Ta | -40~+85℃ |
Storage temperature Ts | -45~+90℃ |
Weight m | ≤850g |
Insulation withstand voltage | |
Withstand voltage | 3.8kV |
![]() |
1us Response 1000A Hall Effect Current Sensor EN50178 Images |